PCB, IMI社 국내총판독점대리점

PCB사 한국정식대리점 Sensor Cables

PCB, IMI 진동 가속도 센서 한국대리점 (KTM) 2025. 5. 21. 15:21

Sensor Cables


PCB Piezotronics
https://www.pcb.com › sensors-for-test-measurement › c...
 
 
 
PCB® manufactures a wide variety of cables that will mate to different sensor types, signal conditioners and data acquisition systems.
이미지
 
 
 
 

 

Sensor Cables


PCB® manufactures a wide variety of cable assemblies that will mate to different sensor types, signal conditioners and data acquisition systems.

Cables are an important part of every measurement system. PCB carefully selects different raw cable types from trusted suppliers and time is taken to design cable to connector interfaces that will be reliable. All cable assemblies are produced at one of PCB's manufacturing locations to tightly controlled assembly procedures that ensure durability in various applications and environments.


How to Avoid Sensor Cabling Problems

There are two primary causes of problems with sensor cabling - connecting the sensor to the cable and cable strain relief. In this "Tips from Techs", learn how to avoid problems with intermittent sensor signals and cable failures.




Types of PCB Sensor Cables:

General Purpose Coaxial Cables

Description: General purpose coaxial cables are used with single axis ICP® sensors. This table provides relevant specifications for four cable types. Type 002 is the most commonly used, but three other types are also available.

Coaxial Cable Types
 



Model 002 012 018 005
Cable Style General Purpose RG-58/U Flexible, Lightweight Rugged
Jacket Material FEP
(Fluorinated ethylene propylene)
PVC
(Polyvinyl chloride)
PVC
(Polyvinyl chloride)
Polyolefin
Jacket Pros Good tensile strength
Good temperature resistance
Resists abrasion
Good flexibility
Resists abrasion
Good flexibility
Good flexibility
Good chemical resistance
Jacket Cons Less resistant to abrasions or cuts Lower operating temperature Lower operating temperature Lower operating temperature
Temperature Range -130 to +400 °F
-90 to +204 °C
-40 to +176 °F
-40 to +80 °C
-22 to +221 °F
-30 to +105 °C
-67 to +275 °F
-55 to +135 °C
Cable Jacket Diameter 0.075 in
1.9 mm
0.193 in
4.9 mm
0.054 in
1.37 mm
0.200 in
5.08 mm
Pull Strength 50 lb 47 lb 7 lb 55 lb
Bend Radius 1.0 in
20 mm
2.0 in
50 mm
.4 in
14 mm
2.0 in
50 mm
Center Conductor Style Stranded Solid Solid Stranded
Capacitance 29 pF/ft
95 pF/m
29 pF/ft
95 pF/m
55 pF/ft
180 pF/m
29 pF/ft
95 pF/m
Shield Type
Coverage
Braid
95% minimum
Braid
95% minimum
Braid
92% minimum
Braid
90% minimum
Complete specifications 002 012 018 005

Low Noise Coaxial Cables

Low noise coaxial cables are used with single axis and triaxial charge mode sensors. This table provides relevant specifications for four cable types. Type 003 is the most commonly used, but three other types are also available.

Low Noise Coaxial Cable Types
 




Model 003 030 006 038 098
Cable Style General Purpose Miniature, Flexible Rugged Rugged Flexible
Jacket Material TFE (Tetrafluoroethylene) FEP (Fluorinated ethylene propylene) Polyolefin Polyurethane TFE (Tetrafluoroethylene)
Jacket Pros Good tensile strength Good flexibility Good tensile strength Good flexibility Good flexibility Good chemical resistance Excellent abrasion resistance, High tear strength Good tensile strength Good flexibility
Jacket Cons Does not resist abrasions or cuts Does not resist abrasions or cuts Lower operating temperature Lower operating temperature Does not resist abrasions or cuts
Temperature Range -320 to +500 °F -196 to +260 °C -130 to +500 °F -90 to +260 °C -67 to +275 °F -55 to +135 °C -58 to +250 °F -50 to +121 °C -130 to +500 °F -90 to +260 °C
Cable Jacket Diameter 0.079 in  2.01 mm 0.042 in  1.09 mm 0.200 in    5.08 mm 0.079 in    2.01 mm 0.079 in  2.06 mm
Pull Strength 75 lb 10 lb 65 lb - lb 24 lb
Bend Radius 1.0 in 25.4 mm .5 in 11 mm 2.0 in 50 mm 1.25 in 30 mm 1.0 in 25.4 mm
Center Conductor Style Solid Stranded Solid Solid Stranded
Conductor AWG 29 awg 34 awg (7/42) 29 awg 29 awg 30 awg (7/38)
Capacitance 30 pF/ft 90 pF/m 30 pF/ft 98 pF/m 30 pF/ft 105 pF/m 30 pF/ft 100 pF/m 35 pF/ft 115 pF/m
           
Shield Type Coverage Braid 90% minimum Braid 90% minimum Braid 90% minimum Braid 90% minimum Braid 90% minimum
Full specifications 003 030 006 038 098

4-conductor Cables

4-conductor cables are used with ICP® triaxial sensors and single axis MEMS sensors. This table provides the most relevant specifications for five cable types. Type 010 and 034 are the most commonly used, but three other types are also available.

4-Conductor Cable Types
 





Model 010 034 019 036 068 078
Cable Style General Purpose General Purpose, Low Noise Flexible, Lightweight Flexible Low Outgassing Rugged, Low Noise
Jacket Material FEP (Fluorinated ethylene propylene) FEP (Fluorinated ethylene propylene) Silicone Silicone FEP (Fluorinated ethylene propylene) Polyurethane
Jacket Pros Good tensile strength Good temperature resistance Good tensile strength Good temperature resistance Excellent flexibility Excellent temperature resistance Excellent flexibility Excellent temperature resistance Good tensile strength Good temperature resistance Resists abrasions and cuts
Jacket Cons Less resistant to abrasions or cuts Less resistant to  abrasions or cuts Low tensile strength and tears easily Low tensile strength and tears easily Less resistant to abrasions or cuts Lower operating temperature
Temperature Range -130 to +392 °F -90 to +200 °C -130 to +392 °F -90 to +200 °C -76 to +500 °F -60 to +260 °C -76 to +392 °F -60 to +200 °C -130 to +392 °F -90 to +200 °C -58 to +185 °F -50 to +85 °C
Cable Jacket Diameter 0.1 in 2.54 mm 0.077 in 1.96 mm 0.070 in 1.77 mm 0.104 in 2.64 mm 0.063 in 1.60 mm 0.119 in 3.02 mm
Pull Strength 34 lb 19 lb 10 lb 30 lb - lb 25 lb
Bend Radius 1.0 in 25.4 mm 1.0 in 25.4 mm 1.0 in 25.4 mm 1.0 in 25.4 mm 1.0 in 25.4 mm 1.0 in 25.4 mm
Center Conductor Style Stranded Solid Solid Stranded Stranded Solid
Conductor AWG 30 awg (7/38) 34 awg 36 awg 32 awg (7/40) 32 awg (7/40) 34 awg
Capacitance (conductor to conductor) 16 pF/ft 52.4 pF/m 14 pF/ft 46 pF/m 15 pF/ft 49.2 pF/m 15 pF/ft 48 pF/m 18 pF/ft 52 pF/m 14 pF/ft 47 pF/m
Capacitance (conductor to shield) 25.8 pF/ft 84.6 pF/m 25 pF/ft 84 pF/m 26 pF/ft 85.2 pF/m 24 pF/ft 76.8 pF/m 28 pF/ft 84.6 pF/m 24.8 pF/ft 81 pF/m
Shield Type Coverage Braid 90% minimum Braid 90% minimum Braid 90% minimum Braid 90% minimum Braid 85% minimum Braid 90% minimum
Full specifications 010 034 019 036 068 078

Multi-Conductor Cables

16 Channel, multi-conductor cables are shielded and wired for PCB® equipment specifically. Shielding minimizes noise when located near other power or signal cables. Custom versions are also available on request. Instrumentation-grade BNC / DB-50 connectors are provided to interface with Patch Panels and Signal Conditioners.

Multi-Conductor Cables
 






Model 009A10 009V15 009M220/005 009H50 009F10 009B00/010 009N03
Cable Style Multi-Conductor - Ruggedized Multi-Conductor - General Multi-Conductor - Ruggedized Multi-Conductor - Ribbon Multi-Conductor - Ribbon Multi-Conductor - Ruggedized Multi-Conductor - Ribbon Multi-Conductor - Ribbon
Description Multi-conductor shielded cable, ruggedized, 10-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY) Multi-conductor shielded cable, 15-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY) Multi-conductor shielded cable, ruggedized, 10-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY) Multi-conductor, shielded flat ribbon cable, 50-ft, DB50 female to DB50 male (Wired for PCB equipment ONLY) Multi-conductor, unshielded flat ribbon cable, 10-ft, DB50 female to DB50 male (Wired for PCB equipment ONLY) Multi-conductor shielded cable, ruggedized, 10-ft, DB50 female to DB50 male (Wired for PCB equipment ONLY) Multi-conductor, unshielded flat ribbon cable, 10-ft, DB50 female to DB50 male (Wired for PCB equipment ONLY)
Jacket Material PVC FEP PVC PVC PVC PVC PVC
Type of Use Patch Panel & DAQ Patch Panel & DAQ Patch Panel & DAQ Gender Changer Gender Changer Gender Changer Communication Cable
Connector 1 DB50 Female DB50 Female DB50 Female DB50 Female DB50 Female DB50 Female 9-pin Female
Connector 2 (16) BNC Plug (16) BNC Plug (16) BNC Plug w/ Drain DB50 Male DB50 Male DB50 Male 9-pin Male & 9-pin Female
Length 10 ft (3 m) 15ft (4.6 m) 5 ft (1.5 m) 50 ft (15.3 m) 10 ft (3 m) 10 ft (3 m) 3ft (0.9 m)
Temperature Range -31 to 167 °F (-35 to +75 °C) -85 to 212 °F (-65 to +100 °C) -31 to 167 °F (-35 to +75 °C) -31 to 221 °F (-35 to +105 °C) -40 to 221 °F (-40 to +105 °C) -31 to 167 °F (-35 to +75 °C) -40 to 221 °F (-40 to +105 °C)
Nominal Cable Size Æ0.63 in (16 mm) Æ0.075 in (1.9 mm) Æ0.63 in (16 mm) 0.12 in (2.9 mm) Thick 0.04 in (0.9 mm) Thick Æ0.63 in (16 mm) 0.04 in (0.9 mm) Thick
Bend Radius 6.5 in (16.5 cm) 0.8 in (20 cm) 6.5 in (16.5 cm) 6.5 in (16.5 cm)
Cable Bulk Weight 225 lbs per 1000 ft 6.25 lb per 1000 ft 225 lbs per 1000 ft 225 lbs per 1000 ft
Center Conductor Style Stranded, shielded twisted pair Stranded, coax Stranded, shielded twisted pair Stranded, shielded ribbon Stranded, unshielded ribbon Stranded, shielded twisted pair Stranded, unshielded ribbon
Center Conductor Material Tinned Copper Silver Copper Covered Steel Tinned Copper Tinned Copper Tinned Copper Tinned Copper Tinned Copper
Conductor Size 24 AWG (7/32) 30 AWG (7/38) 24 AWG (7/32) 28 AWG (7/36) 28 AWG (7/36) 24 AWG (7/32) 28 AWG (7/36)
Shield Type Coverage Inner/Outer: Foil w/ Drain Braid Inner/Outer: Foil w/ Drain Foil w/ Dual Drain Inner/Outer: Foil w/ Drain
Full specifications 009A10 009V15 009M220/005 009H50 009F10 009B00/010 009N03

Cable Test Box



Learn More

Cables are a critical part of any sensor measurement system and damaged cables cause frequent delays during test setup. PCB has developed a relatively simple device to test cables on a channel by channel basis for BNC, 10-32, and 5-44 coaxial connectors. Simply connect both ends of the cable and faults will be indicated for shield failure, conductor failure, or short circuit shield to conductor. Power is provided by a single, replaceable 9 volt battery.

Highlights:

  • Fault indications for shield, conductor, or short circuit
  • Compact and Portable
  • Battery operation (9V)
  • Easy-to-use

Applications:

  • Validate cables pre and post-test to insure data integrity
  • Vibration, acoustic, pressure, force testing
  • Suitable for use during test setup or in cable re-validation

 

Choose PCB sensor cables for your research & development needs

To discuss specific applications, please contact us or request a quote. You can also visit our online shop to find in stock sensors.

Find, Compare or Shop Cables

Download A Catalog

 

 

PCB Piezotronics / IMI Sensors 국내총판대리점 - 케이티엠엔지니어링

PCB Piezotronics / IMI Sensors Domestic Distributor - KTM Engineering

PCB Piezotronics / IMI Sensors Exclusive distributor in Korea - KTM Engineering

산업용 센서 / 진동센서 / 진동엔지니어링 / PCB진동센서 / PCB가속도센서 / PCB사진동센서 / PCB사가속도센서 / IMI진동센서 / IMI가속도센서 /

TMS진동캘리브레이터 / TMS Proximity Transducer Calibrator / TMS Portable Vibration Calibrator

-> 케이티엠엔지니어링이 정식 한국대리점입니다.

PCB Piezotronics 사업부인 IMI Sensors, THE MODAL SHOP 가속도계, 진동 트랜스미터 및 진동캘리브레이터 같은 산업용 진동 모니터링 기기의 글로벌 설계 제조업체입니다.

국내독점 정식대리점에서 고객 맞춤 서비스를 제공하여 드립니다.

진동, 변위, 하중, 응력 (, 무선) 측정 전문업체

()케이티엠엔지니어링

전화: 031-628-6078

메일: dyk@ktme.com |홈페이지: http://www.ktmeng.com

주소: 경기도 성남시 분당구 대왕판교로 670 유스페이스2 B 808